Friday, July 2, 2010
July 1st
Yesterday I began analyzing my results from the previous day's testing. The results seem to show a clear pattern, for as more Mg is added to the initial solution, more Mg is precipitated, suggesting it out competes the Cohex. In general though, as more Mg was added, less DNA is found in solution, suggesting that Mg does not precipitate the DNA nearly as well. I also began working on a report that shows my process and an overview of my results so far. I also prepared another set of samples that should be exactly the same as the ones I ran the last few days. Running these samples again should give me a data set large enough to get some good statistics for my results.
Thursday, July 1, 2010
June 30
Today I spent the day making new timed digestion samples that we could run in the DNA gels. After I finished the final bath that the samples take in 50 celcius I created 10X solutions with each of the time trials because last time we made a gel it was very bright which is an indication that there is too much DNA. We ran the DNA gels overnight and tomorrow we are going to dye them and see our results
Wednesday, June 30, 2010
June 30th
I finally have real, tangible, reasonable results from our collaborator's samples! I spent the morning making new calibration standards and a new set of test samples. I also started reading an article about questionably-plausible applications of this research in gene therapy. It also has applications in designing safer and more effective drugs, as well as learning how viruses pack DNA so efficiently, which would help us fight them. Anyway, the results look fairly consistent at least, I would say accurate but I'm not sure we know what they're supposed to look like. There may be one outlying point that I need to check into, it's possible that I messed up the preparation. The results seem to be telling me things, I'm just not sure what those things are yet. It is clear from the results that as you go up the series of increasing initial magnesium concentrations, the final results are that the magnesium out-competes the cohex. The unknown part is how and why this happens.
June 29
Today we got back our DNA gel and were surprised to find that each of the trials seemed to be very similar even the zero digestion sample. After a lot of thought the professor determined that the process we did for digesting the nucleosomes earlier was around 100 times off than the recommended so that our samples were not originally digested all the way that we wanted. Tomorrow I am going to run a timed digestion again except this time we are going use more nuclease in order to make up for the digestion that we haven't done yet.
Tuesday, June 29, 2010
DNA Gels and Poor Digestion
As Travis mentioned in an earlier post, today we finished running our gel. With the help of the Steve James lab, we imaged our DNA. The results were not promising.
What you see on the left is just the DNA ladder. Those numbers correspond to the number of base pairs (bp). On the right, in the lane labeled 1, you see our DNA ladder with red lines tracing the corresponding markers. As you can see, we can clearly see the 330bp and 100bp markers. What we can't see are all of those nice little lines in between. This could be a problem in the future, but is small beans compared to the mess further to the right.
In lanes 2-12, we had placed DNA samples that had gone through various times of digestion. What we were trying to do was take DNA that was all kinds of different lengths and snip most of it down to 146bp. Each lane corresponds to 5 minutes later than the one before it. So lane 2 is time zero, lane 3 is 5 minutes of digestion, lane 4 is 10 minutes of digestion, and so on. Now, you don't have to be an expert to realize that lane 2 looks identical to lane 12! This is a bad sign. But what does it mean?
There could be many issues: The gel could have been run incorrectly, the samples could be contaminated, or we could have so much DNA (gels aren't normally this bright) that it somehow makes us unable to see what is actually happening. But I'm pretty sure none of these are the cause.
The procedure for digestion I used was a modification to the procedure I had used the first time I did a nucleosome preparation. The modification required a few more measurements, but it was claimed in the paper I pulled it from that this procedure gave better results (i.e. more nucleosomes at the end). We did these extra measurements (I believe correctly) and added the amount of nuclease (the digestors or eaters of the DNA) that the new procedure called for. However, as both Travis and I found out in later calculations (that perhaps should have been done before the trial digestion) this new procedure called for 100 times less nuclease than the former procedure called for. The final result: No digestion.
Luckily enough a) We were doing a trial digestion, not the real thing, so we didn't lose any real amount of samples and b) It is quite easy to repeat the trial digestion with the old method and then rerun our gel. And that's exactly what we are going to do tomorrow.
Wish us luck.
What you see on the left is just the DNA ladder. Those numbers correspond to the number of base pairs (bp). On the right, in the lane labeled 1, you see our DNA ladder with red lines tracing the corresponding markers. As you can see, we can clearly see the 330bp and 100bp markers. What we can't see are all of those nice little lines in between. This could be a problem in the future, but is small beans compared to the mess further to the right.
In lanes 2-12, we had placed DNA samples that had gone through various times of digestion. What we were trying to do was take DNA that was all kinds of different lengths and snip most of it down to 146bp. Each lane corresponds to 5 minutes later than the one before it. So lane 2 is time zero, lane 3 is 5 minutes of digestion, lane 4 is 10 minutes of digestion, and so on. Now, you don't have to be an expert to realize that lane 2 looks identical to lane 12! This is a bad sign. But what does it mean?
There could be many issues: The gel could have been run incorrectly, the samples could be contaminated, or we could have so much DNA (gels aren't normally this bright) that it somehow makes us unable to see what is actually happening. But I'm pretty sure none of these are the cause.
The procedure for digestion I used was a modification to the procedure I had used the first time I did a nucleosome preparation. The modification required a few more measurements, but it was claimed in the paper I pulled it from that this procedure gave better results (i.e. more nucleosomes at the end). We did these extra measurements (I believe correctly) and added the amount of nuclease (the digestors or eaters of the DNA) that the new procedure called for. However, as both Travis and I found out in later calculations (that perhaps should have been done before the trial digestion) this new procedure called for 100 times less nuclease than the former procedure called for. The final result: No digestion.
Luckily enough a) We were doing a trial digestion, not the real thing, so we didn't lose any real amount of samples and b) It is quite easy to repeat the trial digestion with the old method and then rerun our gel. And that's exactly what we are going to do tomorrow.
Wish us luck.
June 29th
This morning, I analyzed the results from my first tests on the real samples. Unfortunately, the machine was not properly calibrated to work well at such low concentrations. The pattern we were expecting to see was for the magnesium concentrations to increase across the series, and for the cobalt and phosphorus concentrations to decrease. The data slightly resembled these trends, but it was also riddled with confusing negative values. These negative values are what suggest that the machine is not calibrated properly. After lunch, I set out to see if the machine could be calibrated to be accurate at very small concentrations. I diluted my previous calibration series X100, because that is more around the range we are dealing with. This is because we diluted the samples X100 to try and conserve the sample if possible. I ran the tests this afternoon, and from my first look, it appears that the machine works quite well at the single parts per billion range, which is impressive. I should be able to start getting realistic data on the real samples tomorrow. One problem that I did have yesterday was that as I was running the real samples, the plasma torch was burning bright orange, and it seemed much stronger than normal. This is disturbing both because it could be damaging the machine, and it will almost definitely throw the results off slightly. I also got a strange error about mercury lines this morning, but it seems everything is alright.
June 28
Today we ran our DNA samples that had been eaten with the nuclease and then stopped with the EDTA through a DNA gel which measure how many base pairs are present in the DNA. It does the by running a current through the gel and the very negative DNA moves towards the positive end of the current. The smaller the base pair number the faster the DNA moves so the higher base pairs would be at the top of the gel and the lower at the bottom. Because it was running so slow we turned the voltage down and allowed the gel to run overnight, and tomorrow we are going to dye the gel and look at it with a UV light.
Monday, June 28, 2010
June 28th
Today I continued my research into the Poisson-Boltzmann equation, as well as into an experiment done previously by Professor Andresen. His experiment used X-ray scattering instead of an OES, but I found one of his results to be very interesting and relevant to the experiments that we are doing now. He found that inter-DNA attractions began somewhere in between 1 ion per 5 base pairs and 1 ion per 4 base pairs. This is particularly interesting because the inter-DNA forces are what we are investigating, and our results should bare some resemblance to these numbers. In the afternoon, I began running the actual samples from our collaborator. I started with the first series, which is 1mM Co and ranges from 0mM Mg to 22.5 mMMg. I used a 100X dilution of these starting values though. I will analyze the results that I got tomorrow. I think that the concentrations might be a bit too low for accurate results, but they should give us a good first impression of what to expect.
June 24
On Thursday we took our final nucleosome solution and mixed a small amount of it with nuclease which ate the DNA that was between the nucleosomes. We put this mixture into a 37 degree Celsius bath and at 5 minute intervals took out a small portion and put it into a separate test tube that we then added EDTA to in order to stop all protein from working. This made sure that the nuclease would stop eating at our nucleosomes. We did this in order to determine how long we need to allow nuclease to eat at our nucleosomes to get the most single nucleosomes that we can. On Monday we are going to see how many base pairs we have in each of our timed solutions through DNA gels which when compared to a known amount of base pairs will tell us which solutions are best.
June 24th-25th
On Thursday, we continued our DNA production process. Our main goal Thursday was to conduct a trial digestion of a small sample of DNA to find the right amount of time to let it digest for. This essentially ruined the sample of DNA, but was necessary so we know how long to digest the rest. To do this, we split a small amount up into ten samples, and put in micrococcal nuclease. Then we let the samples digest, and stopped them in 5 minute intervals. When we analyze these samples, they should give us a good idea of how long to digest the rest. In the afternoon, I did some more research and worked on my presentation for Friday.
On Friday, we had our group meeting, and everyone gave presentations on their research. This went pretty well, but it took the majority of the morning. Because we had put in too many hours earlier in the week, we took the rest of the day off.
On Friday, we had our group meeting, and everyone gave presentations on their research. This went pretty well, but it took the majority of the morning. Because we had put in too many hours earlier in the week, we took the rest of the day off.
Thursday, June 24, 2010
June 23rd
Yesterday we continued the filtration of our DNA sample with additional centrifugation and stirring. We then proceeded to change the buffer of the solution by placing it in a dialysis bag with a different solution surrounding it overnight. I then ran a final test on my calibration of the spectrometer, in preparation to start testing on the actual samples today or tomorrow. I prepared three solutions of known concentration, and the results were fairly accurate, which is good. There seemed to be something wrong with the axial readings, because they were all negative, with very little intensity. We're going to do some maintenance on the spectrometer today and that should fix everything up. I also continued reading the electrostatics paper, and with Professor Andresen's help it began to make sense. I now know a bit more about the actual physics behind the competition of ions to be attracted to DNA, which is exactly what my tests will be studying as well.
June 23
Today we finished our last rinse and spin to get our the rest of the floating junk from our DNA samples. After we pi-petted out the clear leftovers we then dropped them in a dialysis tube in a Tris, Sodium, EDTA bath and left the chromatin dialyzes over night. I then continued reading my paper on Chromatin for my presentation Monday.
Tuesday, June 22, 2010
June 22nd
Today we worked on obtaining actual DNA from our red blood cell samples. This process consists of several repetitions of filtering and putting the solutions in the centrifuge. This also required the use of several different solutions that we prepared, including Tris/HCl, PMSF, EDTA and micrococcal nuclease. After essentially causing the red blood cells to explode, we used the micrococcal nuclease to eat away at the remaining substance. We controlled this reaction by controlling the temperature (putting it on ice) and by introducing EDTA to remove the calcium from solution.
June 22
Today we started the long process of separating out the nucleosomes from the red blood cells. we began by washing and centrifuging the red blood cells 4 times until basically the red had separated and we were left with a semi snotty mixture. we then cleaned the snotty nucleosomes again and collected the final solutions and combined them. We then added a mixture that broke up the nucleosomes and made them less gooey and then centrifuged again and took the liquid that was left over and tested the absorption of the leftovers and got a strange step graph where 260 nm was the middle stem. We are currently adding a salt mixture and about to do more centrifuging
June 21th
Yesterday I started the day by analyzing my results from the previous day. These results were by far the most accurate, but there were still a few issues. For some reason, when I ran the calibration series as a sample, they all were read very accurately, all less than 2% error. But for some reason my other series was still 4-8 % off. This leads me to believe that this solution wasn't prepared correctly, because the spectrometer is clearly calibrated correctly now. It would seem that spacing the calibration samples linearly and using a non-linear yields the best calibration. Later this week I will carefully prepare a new sample series just to confirm this. I also began reading another electrostatics paper that I will try and present on Friday.
Friday, June 18, 2010
Ordering and thinking
I'll let everyone reading this blog in on a little secret. A good portion of a researcher's time is spent on menial tasks and tasks that look very similar to "doing nothing". Today was one such day for me (as was much of the week). I spent most of my time ordering supplies, running around borrowing/stealing supplies from others, and planning our future projects. This last one was the most difficult, as my brain has just not been cooperating lately. People will say that this is related to the 1-month-old baby in my house, but I personally just think it's just the consequence of a more-hectic-than-normal week. To at least a little justify my presence in the lab, I poured a very dangerous powder, PMSF, into isopropyl alcohol to make a slightly less dangerous solution. (Less dangerous because it's a lot harder to inhale a liquid than a dust.)
In real news, we are going to be doing two rather important things next week. First, we are making our nucleosomes. This is exciting, although perhaps a bit early. It's early because it is questionable whether we will have everything we need ready by that time. However, in science it is often the case that you must go ahead with plans and hope for the best. If you wait until everything seems to be ready, you never get anything done. The good news is that our Fisher rep claims our UV detector is coming on Monday. With some luck and some help from Prof. Brandauer in Health Sciences, we should be able to get that up and running on Monday. Additionally, I'm hoping to make all of the stock solutions we need on Monday so that we aren't running around trying to make those all last minute. Our collaborator, Xiangyun Qiu, is coming on Tuesday to see the prep and generally just to visit, so it this coming week should be busy.
The other exciting thing is that I'm expecting to start running the condensed DNA samples that John has been preparing the machine for. Although he's still having a hard time nailing down that last 2-3% of systematic error, I think we're pretty close to being at a place that we can run at. I'm guessing that come Friday or so, we'll be in business. As Xiangyun is the one that gave us these samples, we'll also take some time during his visit to talk to him about the samples and our general running procedure.
So it should be an exciting first week of "summer".
In real news, we are going to be doing two rather important things next week. First, we are making our nucleosomes. This is exciting, although perhaps a bit early. It's early because it is questionable whether we will have everything we need ready by that time. However, in science it is often the case that you must go ahead with plans and hope for the best. If you wait until everything seems to be ready, you never get anything done. The good news is that our Fisher rep claims our UV detector is coming on Monday. With some luck and some help from Prof. Brandauer in Health Sciences, we should be able to get that up and running on Monday. Additionally, I'm hoping to make all of the stock solutions we need on Monday so that we aren't running around trying to make those all last minute. Our collaborator, Xiangyun Qiu, is coming on Tuesday to see the prep and generally just to visit, so it this coming week should be busy.
The other exciting thing is that I'm expecting to start running the condensed DNA samples that John has been preparing the machine for. Although he's still having a hard time nailing down that last 2-3% of systematic error, I think we're pretty close to being at a place that we can run at. I'm guessing that come Friday or so, we'll be in business. As Xiangyun is the one that gave us these samples, we'll also take some time during his visit to talk to him about the samples and our general running procedure.
So it should be an exciting first week of "summer".
June 18th
Today I tried the forcing the calibration line through zero for the data set I have been working with, and I found that it was no different than the weighted linear fit. I also tried constructing an actual concentration versus reported intensity graph myself, and seeing how to best fit that curve. I found that a polynomial fit worked the best, and my result was exactly what the computer had done for its fit. Next, I designed and prepared a new calibration series, one that is equally spread over the range of concentrations we are working with. We also made a few changes to the testing method the machine uses, changing the amounts of time it is permitted to read each sample. I think that these two changes should help eliminate a lot of the systematic error we have been seeing.
June 17th
Yestereday I investigated more into how the machine calibrates itself. I read all of the help files on the different types of calibrations, and tried three different methods on my latest set of data. These methods were linear, weighted linear, and non-linear. I found that weighted linear and non-linear were more accurate than linear, but neither provided the accuracy that we really need. Today I'm going to try another type of fit that forces the calibration line through 0. I am also going to try plotting a graph of concentration versus intensity on my own, to see how the calibration process works. I'm also going to make another calibration series that is equally spread over the range we will be working in, instead of the logarithmic set we have been using.
Thursday, June 17, 2010
june 17
Today I began by combining 3 nucleosome samples together and using the spectrometer to see how good the sample was. Unfortunately it wasn't a good sample and I kept getting this weird peak in my data at 300nm and then had a slow decline to 220nm. So we skipped those nucleosomes and I tested two more samples that we had. The first had the same curve and the second had the curve we wanted but it was already diluted too much to be of any use to us. After that i tested the last two nucleosome samples that were in the freezer and the first one had kind of the curve we wanted but it peak was from 280-240 nm. The last sample had exactly the peak we wanted but the professor had no idea what was in it. He decided we would go over to the biology department and test the DNA to see how many base pairs it had but we found out we were missing a chemical we needed to do the test so we have to wait. For the rest of the day i spent time gathering supplies and reading up on a similar experiment to the one I'm doing.
Wednesday, June 16, 2010
June 16
Today I took a break from experimenting after yesterdays hectic day. I instead did some reading especially on the diffusion technique I am going to use tomorrow with the old nucleosome samples that we have in the freezer. I am going to use the Mg samples that I made a few weeks ago and run them through the nucleosomes in a centrifuge and measure the amount that is absorbed by the nucleosomes.
Subscribe to: